Application Cases
Retrofit Motor Temperature Monitoring Without Drilling a Single Hole
A plant added temperature monitoring to a fleet of existing motors and pumps using magnetic surface-mount RTDs — no drilling, no shutdown machining — and now catches overheating bearings and cooling failures early.
Industry: Plant maintenance / rotating equipment
Products used: Magnetic surface-mount RTD sensors (Pt100), temperature transmitters (4–20 mA)
The challenge
A production plant wanted temperature trending on a fleet of existing motors and pumps — machines that had been installed for years without any temperature instrumentation. The maintenance team knew overheating was their earliest warning for bearing wear, blocked cooling fins and overload, but the classic solution, drilling and tapping a well into each housing, meant shutdowns, machining on live equipment, and a project that kept being postponed. Handheld spot checks with an infrared gun were inconsistent: readings depended on who measured, where exactly they pointed, and the emissivity of painted surfaces.
The solution
We supplied magnetic surface-mount Pt100 RTDs sized for the plant's motor frames:
- The sensing element sits in a flat-faced magnetic housing that clamps directly onto the motor or bearing housing — installed in minutes per machine, with no drilling, no tapping and no process shutdown.
- Each sensor connects to a compact 4–20 mA temperature transmitter, bringing the readings into the plant's existing monitoring system alongside its other analogue signals.
- A documented mounting position per machine type (same spot on every identical frame) so trends are comparable machine-to-machine and month-to-month — the weakness of the old infrared spot checks.
Surface mounting does read a few degrees below the internal winding temperature, and we were explicit about that with the maintenance team: the value of the installation is the trend and the alarm, not an absolute winding measurement. Each machine's normal baseline was recorded during the first weeks, and alarms were set relative to that baseline.
The result
Within the first quarter, the system flagged two developing problems — a pump whose bearing housing temperature climbed steadily over three weeks (a failing bearing, replaced on a planned stop instead of a breakdown) and a motor whose cooling fins were fouling. The retrofit covered the whole fleet without a single machine being opened up, and the plant now has continuous temperature history for its critical rotating equipment.
Why it matters
Most plants have far more rotating equipment than temperature points. Magnetic surface RTDs remove the installation barrier that stops retrofit monitoring projects: when a sensor can be fitted in minutes and moved just as easily, coverage expands from the few "critical" machines to the whole fleet — and condition monitoring becomes a trend you can act on, not a guess.